Interactive 2nd-Order RLC Filter Solver
Type values into any fields (using standard engineering suffixes like m, u, n, k, M) and leave the remaining field empty to solve for it.
Circuit Parameters
Bode Plot (Amplitude & Phase)
Interactive dual-axis AC frequency response (1 Hz to 100 MHz). Move or drag your mouse across the plot to inspect amplitude and phase.
2nd-Order RLC Filter Equations & Design Guidelines
Core transfer equation: f0 = 1/(2π√LC) • ζ = (R/2)√(C/L)
1. 1. Second-Order RLC Transfer Function & Damping
A series RLC network exhibits a 2-pole transfer function with natural frequency f0 = 1/(2π√LC) and damping ratio ζ:
- Damping Ratio (ζ): ζ = (R / 2) × √(C / L) = 1 / (2Q)
- Butterworth (Maximally Flat): ζ = 1/√2 ≈ 0.7071 (Q = 0.7071, no peaking)
- Critically Damped (No Overshoot): ζ = 1.0 (R = 2√(L/C))
2. 2. Resonant Peaking & −40 dB/decade Roll-Off
When ζ < 0.7071 (Q > 0.7071), the magnitude response peaks near f0 with gain |H(f0)| = Q = 1/(2ζ):
- Solve for Damping Resistor R: R = 2 × ζ × √(L / C)
- Solve for L or C: L = C × (R / 2ζ)², C = L × (2ζ / R)²
Using the 2nd-Order RLC Filter Calculator in a Real Design
An inductor and a capacitor together give a second-order filter, rolling off at 40 dB per decade. Its character is set by the damping ratio ζ: below about 0.7 the response peaks at the corner and the step response rings. This is the output filter of every switching converter and class-D amplifier, and the input filter of most power supplies.
Worked example: Damping of a converter’s LC output filter
L = 10 µH and C = 22 µF, with 0.5 Ω of total series resistance.
- f0 = 1 / (2π √(10 µH × 22 µF)) = 10.7 kHz.
- ζ = (R/2) √(C/L) = 0.25 × √2.2 = 0.371.
- Q = 1/(2ζ) = 1.35, so the response peaks by about 2.6 dB at the corner.
What it means: Under-damped: a load step will overshoot and ring at roughly 10 kHz. With only the few milliohms of a real inductor and ceramic capacitor, ζ would be far lower still, which is why the control loop, not the filter, has to provide the damping.
Common mistakes
- An undamped input filter. An LC filter on the input of a switching regulator, with low-ESR ceramics, can have a Q above 10 and rings violently when power is applied. Add a damping branch: a resistor in series with a larger capacitor.
- Interaction with the converter. A regulator’s input looks like a negative resistance. If the filter’s output impedance at resonance exceeds it, the system oscillates.
- Which R. This form of the formula is for resistance in series with the inductor. A resistor across the capacitor damps too, but with the inverse relation: more resistance, less damping.