Home
Ec-SimEE CALCULATORS
Interactive Circuit Design & Direct SPICE Export

RL Filter (LPF / HPF) — Low-Pass Filter (Series L, Shunt R)

Toggle between RL Low-Pass (Series L, Shunt R) and RL High-Pass (Series R, Shunt L) topologies. Solve for cutoff frequency fc = R / (2πL), resistance R, or inductance L.

08 • PASSIVE FILTERS

Interactive RL Filter (LPF / HPF) Solver

Type values into any fields (using standard engineering suffixes like m, u, n, k, M) and leave the remaining field empty to solve for it.

Circuit Parameters

Ω
H
Solve Target
Hz
Interactive Schematic Preview — Click any reference badge to focus its input field
L1 10 mHR1 100 Ωfc 1.592 kHz
−3 dB Corner Frequency (fc)
1.592 kHz
ωc = R/L = 10 krad/s
Inductive Time Constant (τ = L/R)
100 µs
5τ Settling = 500 µs
Inductive Reactance at fc (XL)
100 Ω
XL(fc) = 2π·fc·L = R
RL Low-Pass Response
−45.0° @ fc (−20 dB/dec)
Gain @ fc = −3.01 dB (0.7071 V/V)
Nearest Standard EIA Resistor Values
Snap calculated resistances to standard 5% (E24) or 1% (E96) commercial values:
FREQUENCY RESPONSE

Bode Plot (Amplitude & Phase)

Interactive dual-axis AC frequency response (1 Hz to 100 MHz). Move or drag your mouse across the plot to inspect amplitude and phase.

Hz
Hz
dB
dB
f = 10 kHz● Amp: -16.07 dB● Phase: -81.0°
1 Hz10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz10 MHz100 MHz0 dB+180°-15 dB+90°-30 dB0°-45 dB-90°-60 dB-180°
FORMULAS & THEORY

RL Filter (LPF / HPF) Equations & Design Guidelines

Core transfer equation: fc = R / (2π · L)

1. 1. RL Filter Cutoff & Time Constant

An inductor presents an impedance XL = 2πfL that increases linearly with frequency. Cutoff occurs when XL = R:

  • Cutoff Frequency (fc): fc = R / (2π × L)
  • Solve for Inductance (L): L = R / (2π × fc)
  • Solve for Resistance (R): R = 2π × fc × L

2. 2. Power Chokes & EMI Filtering

RL filters are commonly used in high-current power lines where series resistance must be kept minimal:

  • Time Constant: τ = L / R (seconds)
  • Magnetic Energy: E = ½ × L × I² (Joules)
WORKED EXAMPLE & PRACTICE

Using the RL Filter (LPF / HPF) Calculator in a Real Design

An inductor in series with a resistive load forms a low-pass filter with fc = R/(2πL). The RL form is used where the series element must carry substantial current with little loss: loudspeaker crossovers, motor and solenoid drives, and supply filtering.

Worked example: A woofer crossover inductor

A 1 mH inductor in series with an 8 Ω loudspeaker.

  1. fc = 8 Ω / (2π × 1 mH) = 1273 Hz.
  2. The time constant is L/R = 125 µs.
  3. At 1273 Hz the inductor’s reactance equals the 8 Ω load, so half the amplifier’s output power reaches the woofer.

What it means: Frequencies above about 1.3 kHz are progressively kept out of the woofer, at 6 dB per octave.

Common mistakes

  • Winding resistance. A real inductor has series resistance that adds to the circuit and costs power. An air-core 1 mH coil can easily have 0.5 Ω, which wastes 6% of the amplifier’s output in an 8 Ω system.
  • Saturation. A cored inductor loses inductance as the current approaches its saturation rating, which moves the corner upwards exactly when the signal is largest.
  • The load is not a resistor. A loudspeaker’s impedance rises with frequency and peaks at resonance. The corner calculated with the nominal impedance is only a starting point.