Solve for series resistor Rs, input voltage Vin, Zener voltage Vz, or total current Itotal = Iz + Iload in a Zener diode shunt regulator.

22 • DIODES & REGULATORS

Interactive Zener Shunt Regulator Solver

Type values into any fields (using standard engineering suffixes like m, u, n, k, M) and leave the remaining field empty to solve for it.

Circuit Parameters

V
V
A
Solve Target
Ω
Interactive Schematic Preview — Click any reference badge to focus its input field
Vin 12 VRs 230 ΩItotal 30 mAVz (D1) 5.1 V
Resistor Power (PRs)
207 mW
Use ≥ 1/2 W Power Resistor (2x Derated)
Worst-Case Zener Power (No Load)
153 mW
Pz(max) = Vz · Itotal when Iload = 0
Series Voltage Drop (Vin − Vz)
6.9 V
Headroom = 57.5% of Vin
Recommended Zener Rating
≥ 500 mW (BZX79/BZX84)
2× thermal derating under open-load condition
Nearest Standard EIA Resistor Values
Snap calculated resistances to standard 5% (E24) or 1% (E96) commercial values:
FORMULAS & THEORY

Zener Shunt Regulator Equations & Design Guidelines

Core transfer equation: Rs = (Vin − Vz) / Itotal

1. 1. Zener Shunt Regulation Equations

Operating in reverse breakdown, a Zener diode clamps the output node at Vz as long as reverse Zener current Iz remains above the knee current Izk (typically 5–10 mA):

  • Series Dropping Resistor (Rs): Rs = (Vin − Vz) / (Iz + Iload)
  • Worst-Case Zener Dissipation: Occurs when the external load is disconnected (Iload = 0 → Iz = Itotal).

2. 2. Dynamic Impedance & Ripple Attenuation

A Zener with dynamic impedance Zzt (typically 5–15 Ω for 1N47xxA) forms an AC voltage divider with Rs:

  • Input Ripple Attenuation: ΔVout / ΔVin ≈ Zzt / (Rs + Zzt)
WORKED EXAMPLE & PRACTICE

Using the Zener Shunt Regulator Calculator in a Real Design

A Zener diode with a series resistor makes the simplest voltage regulator. The resistor carries a fixed current; whatever the load does not take flows through the Zener. It suits small, roughly constant loads, voltage references and clamps. For anything above a few tens of milliamperes a linear regulator IC is better in every respect.

Worked example: 5.1 V from a 12 V rail

A 5.1 V Zener, with 20 mA for the load and 5 mA to keep the Zener in regulation: 25 mA in total.

  1. Rs = (12 V − 5.1 V) / 25 mA = 276 Ω. The nearest standard value is 270 Ω.
  2. Rs dissipates 6.9 V × 25.6 mA = 0.18 W.
  3. With the load disconnected the whole 25.6 mA flows in the Zener: 5.1 V × 25.6 mA = 0.13 W.

What it means: 270 Ω at 0.5 W and a 0.5 W Zener. The circuit draws the same 25 mA whether or not the load is using it.

Common mistakes

  • Size the Zener for no load. The worst case for the Zener is the load removed and the input at its maximum. Calculate its dissipation there, not at nominal.
  • Check regulation at minimum input. At the lowest input voltage and the highest load current, the Zener must still carry its minimum current, otherwise the output drops out of regulation.