Home
Ec-SimEE CALCULATORS
Interactive Circuit Design & Direct SPICE Export

Thermal Vias — Plated, Unfilled

Solve for the thermal resistance of a via array, or the hole size, plating, board thickness or number of vias a target needs.

38 • PCB & THERMAL

Interactive Thermal Vias Solver

Type values into any fields (using standard engineering suffixes like m, u, n, k, M) and leave the remaining field empty to solve for it.

Circuit Parameters

mm
µm
mm
Solve Target
°C/W
Interactive Schematic Preview — Click any reference badge to focus its input field
power padheat flows down the copper barrelsd 0.3 mmt 25 µmh 1.6 mmn 9Rθ 21.38 °C/W
One Via
192 °C/W
Copper barrel carries 100.0 % of the heat
Temperature Rise
21.4 °C per W
107 °C at 5 W through the array
Electrical Resistance
1.277 mΩ per via
141.9 µΩ for the array at 20 °C
Current per Via (ΔT = 10 °C)
842.7 mA
≈ 7.584 A for the array (IPC-2221, inner-layer k)
FORMULAS & THEORY

Thermal Vias Equations & Design Guidelines

Core transfer equation: Rθ = h / (n · (k_Cu · π·t·(d − t) + k_fill · π·(d/2 − t)²))

1. 1. Heat Flow Through a Via

A plated via is a thin copper tube through the board. Its wall conducts heat about 1000× better than FR-4:

  • One via: Rθ = h / (k_Cu · A), A = π · t · (d − t) for plating t in a hole of diameter d
  • Array: n vias in parallel: Rθ = Rθ,via / n
  • Fill: Epoxy fill hardly matters thermally; it is used to keep solder from wicking away

2. 2. In a Real Board

The via array is only one link; the copper planes it connects must spread the heat away. Model the whole stack in the 2.5D thermal solver:

  • Pitch: Vias at about 1–1.2 mm pitch under a pad work well; closer pitch adds little.
  • Simulation: Simulate drives 1 A (= 1 W) through Rθ: V(TOP) is the temperature rise in °C.
WORKED EXAMPLE & PRACTICE

Using the Thermal Vias Calculator in a Real Design

Thermal vias carry heat from a component’s pad through the board to copper on the other side. Each via is a thin copper tube, and an array of them is that many tubes in parallel. The calculation gives the resistance of the array, one link in the chain from junction to air.

Worked example: A 3 × 3 array under a power pad

Nine unfilled vias, 0.3 mm drill, 25 µm plating, 1.6 mm board.

  1. Copper cross-section of one barrel = π × t × (d − t) = π × 0.025 × 0.275 = 0.0216 mm².
  2. One via: 1.6 mm / (k_Cu × 0.0216 mm²) ≈ 190 K/W.
  3. Nine in parallel ≈ 21 K/W.

What it means: About 21 K/W through the board, against roughly 590 K/W for the same 3 mm × 3 mm of bare laminate. Note that the plating grows inwards from the drilled diameter.

Common mistakes

  • The array is rarely the bottleneck. Beyond about nine to sixteen vias, the spreading and convection resistance on the far side dominates. More copper area there helps more than more holes.
  • Thermal relief connections. If the CAD tool connects these vias to the plane through spokes, most of the benefit is lost. Set a solid connection for thermal vias.
  • Filling adds little. Epoxy filling, even the “thermally conductive” kind, improves a via by a few percent. Thicker plating is what lowers the resistance.